Friday, July 22, 2011

Getting basic Solaris server information

If you need to know basic software, hardware and load information about a Solaris server then you can use the uname, prstat, psrinfo and prtdiag commands as shown below:

myserver% uname -a
SunOS myserver 5.10 Generic_127127-11 sun4v sparc SUNW,SPARC-Enterprise-T5220

myserver% prstat
PID USERNAME SIZE RSS STATE PRI NICE TIME CPU PROCESS/NLWP
710 root 5504K 2944K sleep 50 0 441:06:31 1.6% inetd/4
1 root 2360K 1168K sleep 59 0 12:17:41 0.7% init/1
26523 oracle 1721M 1700M sleep 59 0 1:37:00 0.4% oracle/1
155 root 6592K 4712K sleep 59 0 88:18:11 0.3% nscd/44
7721 oracle 573M 496M sleep 59 0 0:45:36 0.2% java/98
7110 oracle 1715M 1693M sleep 59 0 0:34:06 0.2% oracle/1
26289 oracle 491M 300M sleep 59 0 0:42:44 0.1% java/44
1500 myuser 1717M 1701M sleep 59 0 0:11:17 0.1% oracle/1
9 root 11M 7992K sleep 59 0 25:23:49 0.1% svc.configd/16
715 root 4424K 2152K sleep 59 0 22:31:24 0.1% syslogd/19
7140 oracle 1770M 1749M sleep 59 0 0:08:52 0.1% oracle/1
8654 myuser 48M 43M sleep 59 0 2:07:15 0.1% uv_scan/1
5707 myuser 1718M 1698M sleep 59 0 1:46:25 0.1% oracle/2
28243 oracle 1715M 1699M sleep 59 0 0:00:04 0.1% oracle/1
8672 myuser 19M 16M sleep 59 0 1:12:42 0.1% uvkd/1
7150 oracle 1714M 1694M sleep 59 0 0:12:46 0.1% oracle/1
8214 root 1416K 936K sleep 53 0 9:09:35 0.1% init.cssd/1
4483 oracle 161M 117M sleep 59 0 0:15:32 0.0% java/21
17881 root 5864K 3704K sleep 50 0 0:00:00 0.0% in.ftpd/1
17880 oracle 2088K 1936K cpu2 58 0 0:00:00 0.0% prstat/1
7092 oracle 1712M 1690M sleep 101 - 0:07:44 0.0% oracle/1
Total: 172 processes, 774 lwps, load averages: 3.92, 2.48, 2.17

myserver% psrinfo -pv
The physical processor has 64 virtual processors (0-63)
UltraSPARC-T2 (cpuid 0 clock 1165 MHz)

myserver% prtdiag
System Configuration: Sun Microsystems sun4v SPARC Enterprise T5220
Memory size: 65408 Megabytes

================================ Virtual CPUs ================================


CPU ID Frequency Implementation Status
------ --------- ---------------------- -------
0 1165 MHz SUNW,UltraSPARC-T2 on-line
1 1165 MHz SUNW,UltraSPARC-T2 on-line
2 1165 MHz SUNW,UltraSPARC-T2 on-line
3 1165 MHz SUNW,UltraSPARC-T2 on-line
4 1165 MHz SUNW,UltraSPARC-T2 on-line
5 1165 MHz SUNW,UltraSPARC-T2 on-line
6 1165 MHz SUNW,UltraSPARC-T2 on-line
7 1165 MHz SUNW,UltraSPARC-T2 on-line
8 1165 MHz SUNW,UltraSPARC-T2 on-line
9 1165 MHz SUNW,UltraSPARC-T2 on-line
10 1165 MHz SUNW,UltraSPARC-T2 on-line
11 1165 MHz SUNW,UltraSPARC-T2 on-line
12 1165 MHz SUNW,UltraSPARC-T2 on-line
13 1165 MHz SUNW,UltraSPARC-T2 on-line
14 1165 MHz SUNW,UltraSPARC-T2 on-line
15 1165 MHz SUNW,UltraSPARC-T2 on-line
16 1165 MHz SUNW,UltraSPARC-T2 on-line
17 1165 MHz SUNW,UltraSPARC-T2 on-line
18 1165 MHz SUNW,UltraSPARC-T2 on-line
19 1165 MHz SUNW,UltraSPARC-T2 on-line
20 1165 MHz SUNW,UltraSPARC-T2 on-line
21 1165 MHz SUNW,UltraSPARC-T2 on-line
22 1165 MHz SUNW,UltraSPARC-T2 on-line
23 1165 MHz SUNW,UltraSPARC-T2 on-line
24 1165 MHz SUNW,UltraSPARC-T2 on-line
25 1165 MHz SUNW,UltraSPARC-T2 on-line
26 1165 MHz SUNW,UltraSPARC-T2 on-line
27 1165 MHz SUNW,UltraSPARC-T2 on-line
28 1165 MHz SUNW,UltraSPARC-T2 on-line
29 1165 MHz SUNW,UltraSPARC-T2 on-line
30 1165 MHz SUNW,UltraSPARC-T2 on-line
31 1165 MHz SUNW,UltraSPARC-T2 on-line
32 1165 MHz SUNW,UltraSPARC-T2 on-line
33 1165 MHz SUNW,UltraSPARC-T2 on-line
34 1165 MHz SUNW,UltraSPARC-T2 on-line
35 1165 MHz SUNW,UltraSPARC-T2 on-line
36 1165 MHz SUNW,UltraSPARC-T2 on-line
37 1165 MHz SUNW,UltraSPARC-T2 on-line
38 1165 MHz SUNW,UltraSPARC-T2 on-line
39 1165 MHz SUNW,UltraSPARC-T2 on-line
40 1165 MHz SUNW,UltraSPARC-T2 on-line
41 1165 MHz SUNW,UltraSPARC-T2 on-line
42 1165 MHz SUNW,UltraSPARC-T2 on-line
43 1165 MHz SUNW,UltraSPARC-T2 on-line
44 1165 MHz SUNW,UltraSPARC-T2 on-line
45 1165 MHz SUNW,UltraSPARC-T2 on-line
46 1165 MHz SUNW,UltraSPARC-T2 on-line
47 1165 MHz SUNW,UltraSPARC-T2 on-line
48 1165 MHz SUNW,UltraSPARC-T2 on-line
49 1165 MHz SUNW,UltraSPARC-T2 on-line
50 1165 MHz SUNW,UltraSPARC-T2 on-line
51 1165 MHz SUNW,UltraSPARC-T2 on-line
52 1165 MHz SUNW,UltraSPARC-T2 on-line
53 1165 MHz SUNW,UltraSPARC-T2 on-line
54 1165 MHz SUNW,UltraSPARC-T2 on-line
55 1165 MHz SUNW,UltraSPARC-T2 on-line
56 1165 MHz SUNW,UltraSPARC-T2 on-line
57 1165 MHz SUNW,UltraSPARC-T2 on-line
58 1165 MHz SUNW,UltraSPARC-T2 on-line
59 1165 MHz SUNW,UltraSPARC-T2 on-line
60 1165 MHz SUNW,UltraSPARC-T2 on-line
61 1165 MHz SUNW,UltraSPARC-T2 on-line
62 1165 MHz SUNW,UltraSPARC-T2 on-line
63 1165 MHz SUNW,UltraSPARC-T2 on-line

======================= Physical Memory Configuration ========================
Segment Table:
--------------------------------------------------------------
Base Segment Interleave Bank Contains
Address Size Factor Size Modules
--------------------------------------------------------------
0x0 64 GB 8 8 GB MB/CMP0/BR0/CH0/D0
MB/CMP0/BR0/CH1/D0
8 GB MB/CMP0/BR0/CH0/D1
MB/CMP0/BR0/CH1/D1
8 GB MB/CMP0/BR1/CH0/D0
MB/CMP0/BR1/CH1/D0
8 GB MB/CMP0/BR1/CH0/D1
MB/CMP0/BR1/CH1/D1
8 GB MB/CMP0/BR2/CH0/D0
MB/CMP0/BR2/CH1/D0
8 GB MB/CMP0/BR2/CH0/D1
MB/CMP0/BR2/CH1/D1
8 GB MB/CMP0/BR3/CH0/D0
MB/CMP0/BR3/CH1/D0
8 GB MB/CMP0/BR3/CH0/D1
MB/CMP0/BR3/CH1/D1


========================= IO Configuration =========================

IO
Location Type Slot Path Name Model
----------- ----- ---- --------------------------------------------- ------------------------- ---------
MB/PCIE PCIE MB /pci@0/pci@0/pci@1/pci@0/pci@1/pci@0 pci-pciexclass,060400
MB/NET0 PCIE MB /pci@0/pci@0/pci@1/pci@0/pci@2/network@0 network-pciex8086,105e
MB/NET1 PCIE MB /pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1 network-pciex8086,105e
MB/NET2 PCIE MB /pci@0/pci@0/pci@1/pci@0/pci@3/network@0 network-pciex8086,105e
MB/NET3 PCIE MB /pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1 network-pciex8086,105e
MB/PCIE PCIE MB /pci@0/pci@0/pci@2/scsi@0 scsi-pciex1000,58 LSI,1068E
MB/PCIE1 PCIE 1 /pci@0/pci@0/pci@8/pci@0/pci@1/SUNW,qlc@0 SUNW,qlc-pciex1077,2432 QLE2460
MB/PCIE4 PCIE 4 /pci@0/pci@0/pci@8/pci@0/pci@2/network@0 network-pciex108e,abcd SUNW,pcie+
MB/PCIE4 PCIE 4 /pci@0/pci@0/pci@8/pci@0/pci@2/network@0,1 network-pciex108e,abcd SUNW,pcie+
MB/PCIE4 PCIE 4 /pci@0/pci@0/pci@8/pci@0/pci@2/network@0,2 network-pciex108e,abcd SUNW,pcie+
MB/PCIE4 PCIE 4 /pci@0/pci@0/pci@8/pci@0/pci@2/network@0,3 network-pciex108e,abcd SUNW,pcie+
MB/PCIE5 PCIE 5 /pci@0/pci@0/pci@8/pci@0/pci@8/pci@0 pci-pciex10b5,8114
MB/PCIE2 PCIE 2 /pci@0/pci@0/pci@9/SUNW,qlc@0 SUNW,qlc-pciex1077,2432 QLE2460

========================= HW Revisions =======================================

System PROM revisions:
----------------------
OBP 4.30.6 2009/12/01 12:40

IO ASIC revisions:
------------------
Location Path Device Revision
-------------------- --------------------------------------------- ------------------------------ ---------
MB/PCI-SWITCH0 /pci@0/pci@0 pciex10b5,8533.aa 170
MB/PCI-SWITCH2 /pci@0/pci@0/pci@1/pci@0 pciex10b5,8517.ac 172
MB/PCI-SWITCH1 /pci@0/pci@0/pci@8/pci@0 pciex10b5,8533.aa 170
MB/GBE0 /pci@0/pci@0/pci@1/pci@0/pci@2/network@0 pciex8086,105e.108e.105e.6 6
MB/GBE0 /pci@0/pci@0/pci@1/pci@0/pci@2/network@0,1 pciex8086,105e.108e.105e.6 6
MB/GBE1 /pci@0/pci@0/pci@1/pci@0/pci@3/network@0 pciex8086,105e.108e.105e.6 6
MB/GBE1 /pci@0/pci@0/pci@1/pci@0/pci@3/network@0,1 pciex8086,105e.108e.105e.6 6
MB/SAS-SATA-HBA /pci@0/pci@0/pci@2/scsi@0 pciex1000,58.1000.1000.4 4

============================ Environmental Status ============================
Fan sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/FANBD0/FM0/F0 TACH ok
SYS/FANBD0/FM0/F1 TACH ok
SYS/FANBD0/FM1/F0 TACH ok
SYS/FANBD0/FM1/F1 TACH ok
SYS/FANBD0/FM2/F0 TACH ok
SYS/FANBD0/FM2/F1 TACH ok

Fan indicators:
------------------------------------------------------------
Location Sensor Condition
------------------------------------------------------------
SYS/PS0 FAN_FAULT ok
SYS/PS1 FAN_FAULT ok

Temperature sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB T_AMB ok
SYS/MB/CMP0/BR0/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR0/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR1/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR2/CH1/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH0/D1 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D0 T_AMB ok
SYS/MB/CMP0/BR3/CH1/D1 T_AMB ok
SYS/MB/CMP0 T_TCORE ok
SYS/MB/CMP0 T_BCORE ok

Temperature indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/PS0 TEMP_FAULT ok
SYS/PS1 TEMP_FAULT ok

Current sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/PS0 I_IN_MAIN ok
SYS/PS0 I_IN_LIMIT ok
SYS/PS0 I_OUT_MAIN ok
SYS/PS0 I_OUT_LIMIT ok
SYS/PS1 I_IN_MAIN ok
SYS/PS1 I_IN_LIMIT ok
SYS/PS1 I_OUT_MAIN ok
SYS/PS1 I_OUT_LIMIT ok

Current indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB I_USB0 ok
SYS/MB I_USB1 ok
SYS/PS0 CUR_FAULT ok
SYS/PS1 CUR_FAULT ok

Voltage sensors:
------------------------------------------------------------
Location Sensor Status
------------------------------------------------------------
SYS/MB V_VMEML ok
SYS/MB V_VMEMR ok
SYS/MB V_+3V3_STBY ok
SYS/MB V_VCORE ok
SYS/MB V_+3V3_MAIN ok
SYS/MB V_VDDIO ok
SYS/MB V_+12V0_MAIN ok
SYS/MB V_VBAT ok
SYS/PS0 V_IN_MAIN ok
SYS/PS0 V_OUT_MAIN ok
SYS/PS1 V_IN_MAIN ok
SYS/PS1 V_OUT_MAIN ok

Voltage indicators:
------------------------------------------------------------
Location Indicator Condition
------------------------------------------------------------
SYS/MB VCORE_POK ok
SYS/MB VMEML_POK ok
SYS/MB VMEMR_POK ok
SYS/PS0 AC_POK ok
SYS/PS0 DC_POK ok
SYS/PS0 VOLT_FAULT ok
SYS/PS1 AC_POK ok
SYS/PS1 DC_POK ok
SYS/PS1 VOLT_FAULT ok

LEDs:
------------------------------------------------------------
Location LED State
------------------------------------------------------------
SYS SERVICE off
SYS LOCATE off
SYS ACT steady
SYS PS_FAULT off
SYS TEMP_FAULT off
SYS FAN_FAULT off
SYS/MB/CMP0/BR0/CH0/D0 SERVICE off
SYS/MB/CMP0/BR0/CH0/D1 SERVICE off
SYS/MB/CMP0/BR0/CH1/D0 SERVICE off
SYS/MB/CMP0/BR0/CH1/D1 SERVICE off
SYS/MB/CMP0/BR1/CH0/D0 SERVICE off
SYS/MB/CMP0/BR1/CH0/D1 SERVICE off
SYS/MB/CMP0/BR1/CH1/D0 SERVICE off
SYS/MB/CMP0/BR1/CH1/D1 SERVICE off
SYS/MB/CMP0/BR2/CH0/D0 SERVICE off
SYS/MB/CMP0/BR2/CH0/D1 SERVICE off
SYS/MB/CMP0/BR2/CH1/D0 SERVICE off
SYS/MB/CMP0/BR2/CH1/D1 SERVICE off
SYS/MB/CMP0/BR3/CH0/D0 SERVICE off
SYS/MB/CMP0/BR3/CH0/D1 SERVICE off
SYS/MB/CMP0/BR3/CH1/D0 SERVICE off
SYS/MB/CMP0/BR3/CH1/D1 SERVICE off
SYS/HDD0 SERVICE off
SYS/HDD0 OK2RM off
SYS/HDD1 SERVICE off
SYS/HDD1 OK2RM off
SYS/HDD2 SERVICE off
SYS/HDD2 OK2RM off
SYS/HDD3 SERVICE off
SYS/HDD3 OK2RM off
SYS/HDD4 SERVICE off
SYS/HDD4 OK2RM off
SYS/HDD5 SERVICE off
SYS/HDD5 OK2RM off
SYS/HDD6 SERVICE off
SYS/HDD6 OK2RM off
SYS/HDD7 SERVICE off
SYS/HDD7 OK2RM off
SYS/FANBD0/FM0 SERVICE off
SYS/FANBD0/FM1 SERVICE off
SYS/FANBD0/FM2 SERVICE off

============================ FRU Status ============================
Location Name Status
------------------------------------------------------
SYS MB enabled
SYS/MB RISER0 enabled
SYS/MB RISER1 enabled
SYS/MB RISER2 enabled
SYS/MB SCC_NVRAM enabled
SYS/MB/CMP0/BR0/CH0 D0 enabled
SYS/MB/CMP0/BR0/CH0 D1 enabled
SYS/MB/CMP0/BR0/CH1 D0 enabled
SYS/MB/CMP0/BR0/CH1 D1 enabled
SYS/MB/CMP0/BR1/CH0 D0 enabled
SYS/MB/CMP0/BR1/CH0 D1 enabled
SYS/MB/CMP0/BR1/CH1 D0 enabled
SYS/MB/CMP0/BR1/CH1 D1 enabled
SYS/MB/CMP0/BR2/CH0 D0 enabled
SYS/MB/CMP0/BR2/CH0 D1 enabled
SYS/MB/CMP0/BR2/CH1 D0 enabled
SYS/MB/CMP0/BR2/CH1 D1 enabled
SYS/MB/CMP0/BR3/CH0 D0 enabled
SYS/MB/CMP0/BR3/CH0 D1 enabled
SYS/MB/CMP0/BR3/CH1 D0 enabled
SYS/MB/CMP0/BR3/CH1 D1 enabled
SYS HDD0 enabled
SYS HDD1 enabled
SYS HDD2 enabled
SYS HDD3 enabled
SYS HDD4 enabled
SYS HDD5 enabled
SYS HDD6 enabled
SYS HDD7 enabled
SYS PDB enabled
SYS SASBP enabled
SYS DVD enabled
SYS USBBD enabled
SYS FANBD0 enabled
SYS/FANBD0 FM0 enabled
SYS/FANBD0 FM1 enabled
SYS/FANBD0 FM2 enabled
SYS FANBD1 enabled
SYS PS0 enabled
SYS PS1 enabled

============================ FW Version ============================
Version
------------------------------------------------------------
Sun System Firmware 7.2.7.d 2010/02/02 17:25


====================== System PROM revisions =======================
Version
------------------------------------------------------------
OBP 4.30.6 2009/12/01 12:40

Chassis Serial Number
---------------------
ABC01234JN

No comments: